Bug #2898

Multiopts don't set tick mark correctly

Added by Leonid Protasov about 4 years ago. Updated about 4 years ago.

Status:FixedStart date:11/15/2015
Priority:HighDue date:
Assignee:Andreas Smas% Done:

100%

Category:User interface
Target version:5.0
Found in version:4.99.400 Platform:Linux

Description

Reproducible in hamburger menu in YTS plugin 0.4.8. Set filter to 1080p for example. Exit plugin, enter it, go to that multiopt - tick is on 3D...

Associated revisions

Revision 74c6bf47
Added by Andreas Smas about 4 years ago

ecmascript/settings: Call callback for multiopt setting after modifying datamodel.

This fixes lag if callback is slow

Refs #2898

Change included in version 4.99.407

Revision 4c17166e
Added by Andreas Smas about 4 years ago

ecmascript: Fix broken multiopt setting

Fixes #2898

Change included in version 4.99.423

History

#1 Updated by Leonid Protasov about 4 years ago

  • Priority changed from Normal to High

Also when you change it, it paints old value and when function of multiop is finished executing, it's redrawn to new... Clearly seen in YTS plugin.

#2 Updated by Andreas Smas about 4 years ago

  • Status changed from New to Fixed
  • % Done changed from 0 to 100

Also available in: Atom PDF